Team,

Power failure, UPS not working in customer place. Now DBCC CHECKDB shows, Data error: cyclic redundancy error. After detach the RPOS7, copy and paste the RPOs7.mdf also shows the same error [See the attached image]

We can follow this: http://support.microsoft.com/kb/319128 to resolve Data cyclic redundancy check error.

If it is not resolved. We must restore previous day backup

There is no backup after Wednesday [05/05/2010]. Finally I have restored it, Customer agreed to reenter those transactions done in last three days. also I told them to maintain UPS properly to avoid such situation in future

Thanks,
ElanGovan Panchatcharam