Item Master Screen: ”Cannot Initialize Data Binding” and “Subscript out of Range”

Error in Master Screen:
Error MSg : ”Cannot Initialize Data Binding” and “Subscript out of Range”

If you face error msg like : Cannot Initialize Data Binding” and “Subscript out of Range”
While open any master screen .

Kindly register the below attached " MSSTDFMT.DLL " & Verify.

How to Manuel unregistered & register the DLL:

Step 1 Do Unregistered the Old DLL
Start - Run - regsvr32 c:windowssystem32MSSTDFMT.DLL -U

Step 2
Rename / Delete the corrupted / Old DLL

Step 3
Copy and paste the exact DLL in OS Path example "c:windowssystem32"
Start - Run - regsvr32 c:windowssystem32MSSTDFMT.DLL

Then you got a message like DLL Registered successfully .

Thanks & Regards,
Muthu Chelvam.S